-5-
Follow-me
The ‘Follow-me’ feature informs the user that events have occurred within their system.
When an event occurs, the control panel dials the user’s telephone number and sounds
two tones. After hearing the two tones, pressing 3, 6, 9 or # on the telephone sounds
additional tones to indicate exactly which type of alarm has occurred. The style of tones
indicates the type of alarm generated.
Series of short tones
= Alarm from burglary zone
1 long tone
= F key alarm or alarm from Fire zone
2 long tones
= E or P key alarms, zone or keypad tamper
After the alarm tones have sounded, pressing 3, 6, 9 or # on the telephone either causes
the control panel to hang up or sound another set of alarm tones if additional alarms have
occurred.
Note: Electronics Line 3000 recommends using a telephone unit with Continuous DTMF mode. If
only Burst mode is available it may be necessary to press more than once. If using the Follow-me
feature, program the relevant event codes with any value greater than 00.
Voice Message (3601)
The 3601 is an add-on module that enables you to record a short message. In the event of
an alarm, the control panel dials the user’s telephone number and this message is played
back. Pressing 3, 6, 9 or # on the telephone acknowledges that the message has been
received.
1.4: Remote Programming
The remote programming software enables programming and operation from a PC. The
software provides a comprehensive interface to the Penta XL series of control panels,
facilitating and cutting down the time taken in programming the system. RP access is
gained using a four digit code programmed at address 81. Without this code all remote
programming and operation is restricted.
Answering Machine Override
Answering machine override enables the control panel to distinguish between regular
incoming calls and a communication attempt by the RP (remote programmer) software. An
RP call is identified by the control panel as a sequence of two calls within a 30-second time
window.
1. The control panel does not answer the first incoming call.
2. The control panel opens a 30-second time window from the moment the
telephone stops ringing.
3. The control panel answers after 1 ring and RP communication is established.
This method enables the panel to share the same telephone line with answering machines
and fax machines.
RP Callback
RP call back is a toll-saver feature that makes remote programming more cost-effective.
When the remote programmer contacts the control panel, the panel hangs up and calls the
telephone number programmed at address 80.