You can connect up to 3 individually addressed LED keypads to the control panel.
To mount the keypad:
1. Separate the front and back cover of the keypad by pressing the locking tabs,
situated at the bottom of the keypad, with a small flathead screwdriver.
2. Pull the keypad wires through the opening in the back cover nearest the
terminal block and mount the back cover to the wall.
3. Define the keypad address by configuring jumpers A & B according to the
following diagram.
Jumper
Removed
Keypad 3Keypad 2Keypad 1
BABAB A
Jumper
Installed
Figure 2.6: Keypad Jumper Configuration
4. Connect the keypad to the control panel according to the following diagram.
+
+
K2
K2
K1
K1
CONTROL PANEL
KEYPAD
3
4
5
6
Figure 2.7: Keypad Connections
5. Reassemble the front and back cover of the keypad.
2.5: Turning on the System
Once all of the systems components are properly connected to their destination terminals,
you are ready to turn the system on. To avoid the risk of electrical shock or damage to the
control panel, make sure that both the AC supply and the battery are connected properly
before plugging in the system. If you experience any difficulties in applying power to the unit,
please contact Electronics Line 3000’s Technical Support Department. The panel is
supplied with a default program that includes typical programming data which means that
minimum programming is required for typical installations.
To turn on the system:
1. Install the JPD jumper located on the control panel board.
2. Reapply power and wait for 10 seconds; the keypad beeps to indicate the end of
the 10 second period.
3. Disconnect both the AC and battery power supply.
4. Remove the JPD jumper.
5. Reapply power and wait for 10 seconds; the keypad beeps to indicate that the
default program has been restored.
The default settings can be reset at any time by disconnnecting the power supply and
repeating the above procedure.